Skip to content

Installation

I. System Configuration

BATCAM FX is a network-based device that is configured by connecting it to a server or user PC with a UTP cable. You can choose the power supply method depending on the installation environment.

  • (Recommended) Use CAT6 or higher UTP cable
  • (Recommended) Maximum cable length within 80 m
  • (Recommended) Use a Gigabit Ethernet connection for FX Viewer

II. Power Supply Methods

1) Using the DC power supply

If a 220 V power source is available at the installation site, use the DC power supply included with the product. Power is supplied through the DC connection terminal on the bottom of the unit.

2) Using a PoE switch or injector

If a 220 V power source is difficult to provide at the installation site, use a separate PoE device. BATCAM FX has built-in PoE, so it can supply both data and power over a single network cable at distances up to 80 m.

  • You must select a PoE+ or higher rated device.
  • When supplying power via PoE, the DC connection terminal must be sealed with the supplied end cap.

III. Mounting and Installation

BATCAM FX is a fixed-mount ultrasonic camera that is installed by fixing it to a wall or post using the VESA 75 holes on the rear of the product.

  • VESA mount detailed specification: VESA75_TAP M4 × 0.7 DP8

Waterproof/Dustproof Installation (Outdoor)

BATCAM FX has IP65-rated water/dust resistance. For outdoor installation, the communication-cable connector must always be joined and installed using the supplied waterproof connector.

Quick Start — Initial Connection

Initial camera registration information

When registering a new camera in FX Viewer, factory-default units use the following default values.

  • IP — 192.168.50.11
  • Port — 80
  • RTSP Port — 8554
  • UserName — admin
  • Password — admin

※ You must fix the PC’s wired network range to 192.168.50.xxx before registering.

Installation precautions

  • When connecting multiple units, change each unit’s network IP address before installation.
  • When changing the IP range, do not use the 192.168.100.xxx range (conflicts with the internal network).

The camera’s angle of view is 62° horizontal, 48° vertical. Depending on the distance to the measurement target, the measurement range that fits in one screen can be estimated as follows.

  • X-axis (horizontal) length (m) = 1.202 × distance (m)
  • Y-axis (vertical) length (m) = 0.890 × distance (m)

For example, if the measurement target is 5 m away, a range of approx. 6.0 m × 4.5 m fits in one screen. Determine the installation distance to match the size of the target equipment.