Troubleshooting
Troubleshooting
This section summarizes common problems that occur while operating BATCAM FX / FX Viewer and how to resolve them.
1. Camera is not found or registered in FX Viewer
Symptoms
- The device does not appear on the camera registration screen
- Connection fails when attempting to connect
Things to check
- The factory-default IP is
192.168.50.11. - The PC’s wired network must be fixed to the
192.168.50.xxxrange. - CAT6 or higher UTP cable is recommended, and installation within 80 m is recommended.
2. RTSP video does not appear
Things to check
- The default RTSP port is
8554. - Connection address example:
rtsp://{device IP}:8554/raw
3. Connection drops after changing the IP
Cause — When you change the device IP, the PC must also be set to the same range.
Caution — Do not use the 192.168.100.xxx range. It overlaps with the device’s internal network and connection will be blocked.
4. PoE power is not supplied
Things to check
- The PoE device must be PoE+ or higher rated.
- When using PoE, the DC connector must be sealed with the supplied end cap.
5. The AI button is disabled in Analysis
Cause
- The AI feature cannot be used on results recorded without AI applied.
- It is only enabled on results to which a trained AI model was applied at the time of recording.
6. Further inquiries
If the above items do not resolve the issue, check the FX Viewer logs and device status information, then contact the developer guide or your representative.