Troubleshooting

Troubleshooting

This section summarizes common problems that occur while operating BATCAM FX / FX Viewer and how to resolve them.

1. Camera is not found or registered in FX Viewer

Symptoms

  • The device does not appear on the camera registration screen
  • Connection fails when attempting to connect

Things to check

  • The factory-default IP is 192.168.50.11.
  • The PC’s wired network must be fixed to the 192.168.50.xxx range.
  • CAT6 or higher UTP cable is recommended, and installation within 80 m is recommended.

2. RTSP video does not appear

Things to check

  • The default RTSP port is 8554.
  • Connection address example: rtsp://{device IP}:8554/raw

3. Connection drops after changing the IP

Cause — When you change the device IP, the PC must also be set to the same range.

Caution — Do not use the 192.168.100.xxx range. It overlaps with the device’s internal network and connection will be blocked.

4. PoE power is not supplied

Things to check

  • The PoE device must be PoE+ or higher rated.
  • When using PoE, the DC connector must be sealed with the supplied end cap.

5. The AI button is disabled in Analysis

Cause

  • The AI feature cannot be used on results recorded without AI applied.
  • It is only enabled on results to which a trained AI model was applied at the time of recording.

6. Further inquiries

If the above items do not resolve the issue, check the FX Viewer logs and device status information, then contact the developer guide or your representative.