Skip to content

Frequently Asked Questions

Frequently asked questions and answers about BATCAM FX2 are grouped by category. For solutions by symptom, see Troubleshooting.

Product

Q. What is BATCAM FX2?

It is a fixed ultrasonic camera equipped with a 112-channel MEMS microphone array and a camera. It displays the location of a sound as a heatmap over the video.

Q. What camera models are available?

There are two: SMIA462 Wide and SMI3708 Wide. To check which one is installed, see Camera Model under Home → Device Information. Both cameras provide video at 1920 × 1080 (default), 1600 × 900, 1280 × 720, or 640 × 360 resolution at 25 fps.

Q. What does the AI detect?

There is Leak AI (LEAK AI), which identifies compressed-air and gas leaks, and Partial Discharge AI (PD AI), which identifies partial discharge. Both models run on the device.

Q. Can both AI models be enabled at the same time?

No. Only one model can be enabled at a time.

Q. Does the device record video continuously?

The device saves events when the specified conditions are met. It does not record continuously.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

To record continuously on a PC, use FX Viewer 1.1.1 for Windows.

Q. What is the water and dust resistance rating?

It is rated IP68.

Installation and Power

Q. How is power supplied?

Power can be supplied via PoE+ or DC 12 ~ 24 V.

Q. What are the cable requirements for installation?

Use a CAT5e or higher UTP cable; CAT6 is recommended. The installation distance must be within 80 m.

Q. What are the factory-default IP addresses?

The eth0 port uses 192.168.0.80, and the eth1 port uses 192.168.0.81.

Device Manager

Q. What are the default login credentials?

After a factory reset, the administrator account has the ID admin and password 1234. The same values are shown in the notice below the login screen. Change the password after your first login.

Q. Can a regular user account change settings?

It can change measurement settings such as beamforming, camera, and AI settings. Only an administrator account can manage accounts, network settings, time, firmware updates, service restarts, factory resets, and event deletion. In firmware v1.1.0, a regular user account can also change auto-save and level-trigger settings.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

Only an administrator account can change auto-save and level-trigger settings.

Q. What does an event ZIP file contain?

It contains the photos (JPG), videos (MP4), audio (WAV), and measurement data (H5) actually saved for that event. Files that were not saved are not included.

Q. How long are events stored?

Each event covers approximately 2 seconds. When free storage space falls below 10 %, the oldest events are automatically deleted first.

Integration

Q. What is the RTSP stream address?

It is rtsp://<device-ip>:8554/overlay. There is no raw video path (/raw). In firmware v1.1.0, an account is not required to view RTSP video.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

If stream authentication is enabled (the default), a device account is required. Save the credentials in the VMS or viewer, or include them in the address as rtsp://<ID>:<password>@<device-ip>:8554/overlay. RTSP supports Basic authentication only.

Q. What are the rtsp://…:8554/raw address and /fx_…/image video topic mentioned in other documentation?

They apply to BATCAM FX and not to BATCAM FX2. Receive BATCAM FX2 video from rtsp://<device-ip>:8554/overlay. Firmware v1.1.0 does not have a ROS 2 video topic.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

Starting with firmware v1.1.1, video can also be received through the ROS 2 video topic /fx2/<serial-token>/image/compressed. For details, see ROS 2 Integration.

Q. How does the API work?

It uses a REST API and WebSocket. API documentation is available at http://<device-ip>/api-docs.

Q. Is Modbus TCP enabled by default?

No. An administrator enables it in the “Modbus TCP” card on the Events → Trigger Conditions tab.

Q. Does it support ROS 2?

Yes. It supports the Jazzy distribution of ROS 2 and provides five topics and two actions.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

A camera video topic has been added, bringing the total to six topics and two actions.

Q. Do the integration methods require authentication?

The REST API requires a device account. In firmware v1.1.0, RTSP, WebRTC, WebSocket, ONVIF, event files, Modbus TCP, and ROS 2 do not require an account. The device should be used only on an internal network.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

A device account is required to access RTSP, WebRTC, WebSocket, ONVIF snapshots, and event files. An administrator can disable this under Settings → Stream Authentication. ONVIF device discovery and queries, Modbus TCP, and ROS 2 do not require authentication. Anyone in the same DDS domain can view video through the ROS 2 video topic without an account, even when stream authentication is enabled.

Q. Does it support HTTPS?

No. Device Manager and the REST API are accessed over HTTP on port 80.

Firmware

Q. Where can I check the firmware version?

In Device Manager, check “Firmware Version” under Home → Device Information.

Q. Are settings retained after a firmware update?

Settings, accounts, and events are retained.

Q. Can I turn off the power during an update?

No. If power is interrupted before the update is finalized, the device reverts to the previous firmware.

Q. Where can I get the firmware file?

Request the firmware file through Product Support and Inquiries.