1. Cannot access Device Manager

Symptoms

  • Nothing appears when you open the device address in a browser

Checks

  • The factory IP addresses are 192.168.0.80 for the eth0 port and 192.168.0.81 for the eth1 port.
  • The PC must be on the same subnet as the device (192.168.0.xxx).
  • The address is http://<device-ip>. HTTPS is not supported.
  • After changing the device IP address, connect using the new address. If you switched to DHCP, check the DHCP server for the address assigned to the device.

Cause — If you change the device IP address, you must put the PC on the same subnet.

For initial setup, see Getting started.

2. Keep returning to the login screen

Symptoms

  • Returned to the login screen after logging in
  • The login screen suddenly appears during use

Checks

  • Login credentials remain valid for 24 hours. Log in again when they expire.
  • Login credentials are stored in browser cookies. If you clear the cookies, you must log in again.
  • A browser is logged out after a factory reset, so you must log in again.
  • After a factory reset, the administrator account has the ID admin and password 1234. The same values appear in the notice below the login form. You must change the password after your first login.
Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

After updating the firmware to v1.1.1 or performing a factory reset, you must log in again once in every browser and application.

3. Cannot change password

Symptoms

  • Unable to change the password

Checks

  • Standard user accounts cannot change passwords. An administrator account is required.
  • You cannot use the initial password (1234) again.
  • The password must be at least four characters long.
  • “New password” and “Confirm password” must match.

For account management, see User accounts and permissions.

4. “Unable to load information” appears or a list is empty

Symptoms

  • “Unable to load information” appears on the Network Status card on Home
  • The network table or user list in Settings is empty
  • There is no Edit button in Time Settings

Checks

  • Network, user, and time settings require administrator privileges.
  • When you log in with a standard user account, the menus appear but this information is empty.
  • Log in again with an administrator account.

5. Only an “…in progress” message remains after pressing a button

Symptoms

  • After pressing “Restart” under Settings → Restart Service, “Restarting service” remains on the screen

Checks

  • Only an administrator account can restart the service or perform a factory reset.
  • Requests from standard user accounts are denied, but the in-progress message remains on the screen.
  • Log in again with an administrator account and retry.

6. Deletion fails

Symptoms

  • Deleting an event displays “Failed to delete event: no permission”

Checks

  • Only an administrator account can delete events or delete all events.

Video and display

7. No video

Symptoms

  • “Connecting to camera…” or “Disconnected. Reconnecting…” remains on the screen

Checks

  • Device Manager receives video through WebRTC. The browser must support WebRTC.
  • Video will not appear if a firewall or router between the PC and device blocks TCP 8889 or UDP 8189 (the defaults).
  • If the video disconnects, it automatically tries to reconnect. It disconnects for a few seconds immediately after a service restart or a change to video rotation.
  • WebRTC supports up to 10 simultaneous connections.
  • RTSP video is available at rtsp://<device-ip>:8554/overlay. There is no /raw path.

7-1. No video in a VMS or viewer

This section applies to stream authentication in firmware v1.1.1. In firmware v1.1.0, no account is required for RTSP video, WebRTC video, WebSocket, ONVIF snapshots, or event files.

Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

Symptoms

  • A VMS, video viewer, or script cannot retrieve RTSP video, ONVIF snapshots, WebSocket data, or event files
  • A login prompt appears when you open a video or event-file address in a browser

Checks

  • When stream authentication is enabled, a device account is required. Save the device account (ID and password) in the VMS or viewer, or include it in the address, as in rtsp://<ID>:<password>@<device-ip>:8554/overlay. A VMS that registers the device through ONVIF must also save the account.
  • RTSP supports Basic authentication only. Clients that use only Digest authentication cannot connect.
  • When stream authentication is enabled, RTSP multicast is rejected (461). Switch to TCP or UDP unicast.
  • If an incorrect account fails 10 times within one minute, that PC address is blocked for 60 seconds. Correct the account and wait up to 60 seconds.
  • A web page on another site is rejected (403) if it connects using Basic authentication.
  • If you must use a client that cannot provide an account, an administrator can turn off Settings → Stream Authentication. For details, see System settings.

8. Resolution does not change

Symptoms

  • The video size stays the same after changing the resolution in the Camera menu

Checks

  • The resolution takes effect after you use Settings → Restart Service.
  • Until the restart, the RTSP stream and ONVIF retain the previous size.
  • Only an administrator account can restart the service.

9. Cannot change the measurement band

Symptoms

  • The “Frequency Range” slider in the Beamforming menu does not move
  • “The frequency range cannot be changed while AI is running” appears

Checks

  • While AI is running, the measurement band is fixed to the model’s band. PD AI uses 25 kHz ~ 60 kHz, and LEAK AI uses 13 kHz ~ 65 kHz.
  • Turning off AI restores the previously selected measurement band.
  • If you set an AI operating schedule, the band is fixed only during that period.
  • If you move the upper limit to the end of the slider (99 kHz), the setting is not saved. Set the upper limit to 98.9 kHz or lower.

10. Heatmap covers the screen or is not visible

Symptoms

  • Color covers the entire video
  • The heatmap is not visible

Checks

  • “Threshold” in the Beamforming menu is the lower limit for drawing the heatmap. A low value colors even faint sounds; a high value can make the heatmap disappear.
  • “Range” and “Average” also affect the heatmap’s appearance.
  • If the overlay mode is “Overlay Off,” the heatmap is not drawn. Measurement and event storage continue to work.
  • When a region of interest (ROI) is enabled, the heatmap outside the ROI box is not visible.
  • While AI is running, the heatmap appears gray when nothing is detected. Color appears when a detection occurs.

11. Heatmap position does not match the sound source

Symptoms

  • The peak marker and heatmap positions do not match
  • The heatmap does not match the actual location of the sound

Checks

  • Changing “Field of View (FOV)” in the Camera menu also changes the beamforming calibration. Check that the field of view matches the installation.
  • Video rotation applies only to the video. The beamforming overlay does not rotate.
  • In firmware v1.1.0, the heatmap is drawn farther inward than the peak marker near the edges of the screen.
  • If a sound source lies on a grid-cell boundary, the peak marker may alternate between the two neighboring cells.
Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

  • The heatmap appears at the same position as the peak marker.
  • If a field-of-view warning appears on the Camera screen, the model default is being used instead of the device calibration value. Check the reason shown below the warning, and contact the seller or manufacturer if the positions do not match.

For how to change the field of view, see Camera settings.

Events and time

12. No level-trigger event is created

Symptoms

  • No event is saved even when there is a loud sound

Checks

  • On the Events → Trigger Conditions tab, check that the level trigger is enabled. It is enabled by default, with a threshold of 70 dB.
  • If “Threshold” in the Beamforming menu is higher than the level trigger’s “Threshold (dB),” no event is created. Sounds below the beamforming threshold are not identified as peaks.
  • The level trigger compares the peak value after averaging. If there is no peak above the threshold, no event is created.
  • Cooldown is measured from the last event, regardless of event type. If an automatic-save or AI event was just saved, no level-trigger event is created until the cooldown ends.
  • In firmware v1.1.0, triggers added through REST are saved but do not record events.
Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

Triggers added through REST also record events when their conditions are met. Under Custom Triggers in Events, check whether the trigger is enabled, its threshold, and its cooldown.

Note — For a few seconds immediately after an event occurs, the device collects data for that event, so no new event can occur.

13. Too many events are created

Symptoms

  • The event list fills up in a short time

Checks

  • Raise the level trigger’s “Threshold (dB)” or increase “Cooldown (sec).”
  • Check whether “Automatic Save Settings” is enabled. It is off by default.
  • For AI events, raise “Detection Threshold Score” or “Trigger Count,” or increase “Event Save Cooldown (sec).”
  • Check whether the 40 kHz signal generator is on.
  • When free storage falls below 10%, the oldest events are deleted automatically.

14. Event times are incorrect

Symptoms

  • The times in the event list differ from the actual time

Checks

  • Under Settings → Time Settings, check “Time Zone” and the NTP status. If the NTP status is “Synchronized,” the device clock is synchronized with the time server.
  • “Creation Time” in the event list is displayed in the PC browser’s time zone. Recent events on Home are displayed in the device’s time zone. If the two time zones differ, the times on the two screens differ.
  • The time in the status bar over the video is the device time.
  • BATCAM FX2 has no RTC (built-in clock). If the power is turned off while it is disconnected from a time server (NTP), the device loses its time. When powered on without NTP, the device time starts at 1970-01-01T00:00:00. Use an accessible NTP server. On an isolated network, use an on-site NTP server and check the time under Settings → Time Settings after powering on.
  • The Modbus TCP time registers use UTC.

For time settings, see System settings.

Checks and measurements

15. Cannot run Microphone Quality

Symptoms

  • Running Microphone Quality displays “Microphone calibration cannot run while AI is running”

Checks

  • Microphone Quality cannot run while AI is running.
  • Turn off AI in the Artificial Intelligence menu, then run it.

16. The 40 kHz signal generator shows UNKNOWN or measurements are abnormal

Symptoms

  • The current status in the Microphone Channels menu is UNKNOWN, and the button cannot be pressed
  • The measured level is high even though there is no sound

Checks

  • UNKNOWN means the status could not be read or is still being read. Try reopening the screen.
  • If the 40 kHz signal generator is left on, the reference signal is measured instead of the actual sound. This can cause the level trigger to operate incorrectly.
  • The signal generator starts in the off state when the device is powered on again. It does not turn off automatically during operation.

Note — When the check is complete, press “Off” in the Microphone Channels menu to turn off the signal generator.

For the procedure, see Microphone check.

Firmware

17. Update fails or reverts to the previous version

Symptoms

  • The uploaded firmware is not installed, and the device restarts with the same version
  • The device returns to the previous version after updating

Checks

  • Firmware files differ by camera. If the camera model on Home is “SMIA462 Wide,” upload a file whose name starts with fx2-cm5-arducam. If it is “SMI3708 Wide,” upload a file whose name starts with fx2-cm5-imx708.
  • A file for a different camera is rejected, and the device restarts.
  • When the device reboots after an update, the new firmware performs a trial boot. If it operates normally, it is confirmed after about one minute.
  • If the service does not become healthy within 10 minutes, the device automatically reverts to the previous firmware.
  • During trial boot, the device list and Ethernet connection are checked. A device or gateway recorded during installation must respond. The device may revert to the previous firmware if a cable is unplugged between installation and reboot, or if the PC used to upload the firmware is turned off and there is no gateway. In firmware v1.1.0, a device connected directly to a PC through only the eth0 port may also revert if the gateway does not respond. For detailed conditions, see Trial boot and confirmation under Firmware update.
  • Rebooting or losing power before confirmation also causes a return to the previous firmware. Events saved by the new firmware will then not be visible in the previous firmware.
  • A device that reverted before confirmation can be updated again.
  • Only an administrator account can update the firmware.
Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

If there is no response target during trial boot, or the only target is the current gateway, the check can pass based on a record of packets sent and received through an IPv4 port. The issue in which a device connected directly to a PC through only the eth0 port reverted because the gateway did not respond has been fixed. If the PC was recorded alongside the gateway as a connection target during installation and neither responds, the device may still revert to the previous firmware.

Note — You cannot use an update to install firmware older than v1.1.0. If you need older firmware, see Product support and inquiries to get in touch.

For the update procedure, see Firmware update.

18. An FPGA notification appears

Symptoms

  • An FPGA notification appears on the Software Update screen

Checks

  • “Updating FPGA. Do not turn off the power.” — A new FPGA version is being written. The device may restart when this finishes.
  • “FPGA update failed after firmware installation.” — The device continues operating with its current FPGA. It will not retry automatically.
  • “FPGA version could not be read, so no update was attempted.” — If the version cannot be read, it is not written automatically.
  • “FPGA verification is waiting for firmware update confirmation.” — If this persists after a reboot, contact support.

If the update fails or the version cannot be read, you can upload an FPGA file through the “Service/Recovery: Update FPGA Only Manually” link on the Software Update screen. Only an administrator account can upload it.

Note — Do not turn off the power while uploading the FPGA. In firmware v1.1.0, if the version read at the next boot is outside the 2.0.2 ~ 2.0.3 range or is a development build of 2.0.2, the device restores FPGA 2.0.2 included with the firmware.

Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

If the version read at the next boot differs from the official 2.0.3 release, the device restores the official FPGA 2.0.3 release included with the firmware.

Accounts

19. Forgot password

Symptoms

  • Cannot log in

Checks

  • If another administrator account exists, log in with it. Set a new password using “Change Password” for the account in the Users menu.
  • If there is no administrator account, press the rear button for at least three seconds to perform a factory reset.
  • After a factory reset, the administrator account has the ID admin and password 1234. The same values appear in the notice below the login form. You must change the password after your first login.

Note — A factory reset deletes all accounts, settings, and events. This cannot be undone.

Further assistance

20. Further assistance

If these steps do not resolve the issue, check the values under Home → Device Information before contacting support. Provide the device name, device code, serial number, firmware version, FPGA version, and camera model. For contact information, see Product support and inquiries.