Skip to content

Installation

This guide explains how to connect the BATCAM FX2 to a network and power source, choose an installation location, and mount the device. Read the safety and handling precautions before installation.

System configuration

The BATCAM FX2 is a network device. Connect it to a PC, switch, or server with an Ethernet cable. It has two Ethernet ports: eth0 and eth1.

  • eth0 port — Connects to a PC, VMS, PLC, or robot through a switch. Its factory-default address is 192.168.0.80.
  • eth1 port — Connects directly to a PC. Its factory-default address is 192.168.0.81, and it has no gateway.

Diagram showing the eth0 port connected to a PC, VMS, PLC, and robot through a switch; the eth1 port connected directly to a PC; and DC power connected separately

The connector labeled PoE on the multi-cable is the eth0 port. PoE+ power is supplied through this connector.

  • Use a CAT5e or higher UTP cable. A length of 80 m or less is recommended.
  • A Gigabit Ethernet connection is recommended for video and Device Manager access.
  • Fiber-optic cable is recommended for distances over 80 m.

Power supply options

1) Using PoE+

Connecting to a PoE+ (IEEE 802.3at) switch or injector supplies both data and power over a single Ethernet cable. This is suitable for outdoor or elevated locations where separate power wiring is difficult.

2) Using DC power

If DC power is available at the installation location, supply 12–24 V DC. Use only power supplies and cables that meet the specified requirements.

The device boots when power is connected. Measurement begins when the status LED turns green.

Mounting the device

The device can be mounted in two ways.

1) VESA 75 / VESA 100

Bolt a commercially available mount to the VESA 75 or VESA 100 threaded holes on the rear. Make sure the mount can adequately support the device’s weight (approximately 1,245 g).

2) Dedicated bracket

The standard installation kit (swing mount) allows you to adjust the installation angle. Use only the bracket and bolts included in the kit. Tighten the left and right fixing screws securely.

With the dedicated bracket installed, the overall dimensions are 151.9 mm wide, 196.77 mm high, and 95.33 mm deep.

Outline drawing of the device with the dedicated bracket installed

Drawing showing the dimensions and mounting holes of the dedicated bracket

Installation location and field of view

Position the device and set its distance so that the measurement target is centered on the screen and the area to be monitored falls within the field of view. Areas outside the field of view cannot be seen in the image.

At a 100% field-of-view setting, the default horizontal fields of view for the firmware are as follows.

  • SMIA462 Wide — 124.07°
  • SMI3708 Wide — 101.6°

Each device is calibrated before shipment, so actual values may vary slightly. See Camera Settings for the values at 67%, 50%, and 33% field-of-view settings.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

For an SMIA462 Wide device without device-specific calibration values, the default horizontal field of view at the 100% setting is 123.78°.

In the camera menu, you can select “100%”, “67%”, “50%”, or “33%” under “Field of View (FOV)”. Lower values magnify a narrower area.

Aligning the device

During installation, turn on “Crosshair” in the camera menu and align the measurement target with the red crosshair at the center of the screen. Select “Open Preview” under “Installation Adjustment” to check the alignment using snapshots that update at approximately 1.4 fps without video streaming.

Installation Adjustment preview in the camera menu showing the crosshair and the measurement target centered on the screen

For details, see Camera Settings.

Cables and waterproofing

  • The device has an IP68 water- and dust-resistance rating.
  • For outdoor installations, an additional waterproof junction box is recommended around the multi-cable connector joints.
  • For outdoor installations, use the included waterproof PoE connector to protect the Ethernet connector from water and dust.

Installation precautions

  • Do not disconnect or connect cables while power is supplied.
  • Do not obstruct the front of the microphone array or the camera lens.
  • Avoid locations exposed to prolonged direct sunlight or continuous strong vibration.
  • Before connecting multiple devices to the same network, assign a different IP address to each device. For details, see Connecting for the First Time.