Skip to content

Product Specifications and Package Contents

This page describes the hardware specifications of the BATCAM FX2, the features of firmware v1.1.0, and the package contents.

Product Specifications

BATCAM FX2 viewed from the top, front, side, and rear, and mounted on its dedicated stand

  • Product — Fixed ultrasonic camera
  • Model — BATCAM FX2
  • Primary uses — Gas leak detection, partial discharge detection, industrial acoustic monitoring
  • Dimensions (main unit) — Within 148 × 146 × 69 mm (excluding mount and cable gland)
  • Dimensions (overall) — Within 152 × 197 × 96 mm (including mount and cable gland)
  • Weight — Main unit 1,245 g; including cable 1,395 g
  • Color — Black

Acoustics

  • Microphones — Digital MEMS microphones
  • Number of channels — 112
  • Frequency range — 1 kHz ~ 100 kHz
  • Sampling rate — 200 kS/s
  • Bit resolution — 24 bits
  • Measurement range — 5 dB SPL ~ 122 dB SPL (25 kHz ~ 60 kHz, beamforming level)
  • Minimum detectable leak flow rate — 50 cc/min (based on a nitrogen gas leak from a circular micro-nozzle)
  • Effective measurement distance — 0.5 m ~ 200 m
  • Beamforming — FPGA-based real-time processing, 44 × 26 grid map
  • Default measurement band — 20 kHz ~ 60 kHz
  • Self-diagnostics — Microphone check using a built-in 40 kHz reference signal

※ The lower limit of the measurement range is the minimum detection level after applying the processing gain of the 112-channel beamforming array. It differs from the noise floor of a single microphone.

※ The lower limit of the measurement range is the minimum detection level after applying 112-channel beamforming processing gain and differs from the noise floor of a single microphone.

Camera

Depending on the configuration, the device contains one of the following two cameras. Check “Camera Model” on the Device Manager home page to identify it.

SMIA462 Wide

  • Focus adjustment — None
  • Firmware file — fx2-cm5-arducam-v<version>.mender
  • Sensor capture mode — 1920 × 1080
  • Output resolution — 1920 × 1080 (default), 1600 × 900, 1280 × 720, 640 × 360
  • Frame rate — 25 fps
  • Horizontal field of view at 100 % — 124.07°
  • Horizontal field of view at 67 % — 82.71°
  • Horizontal field of view at 50 % — 62.03°
  • Horizontal field of view at 33 % — 41.36°
Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

The default horizontal field-of-view values for SMIA462 Wide devices without device-specific field-of-view calibration have changed as follows.

  • Horizontal field of view at 100 % — 123.78°
  • Horizontal field of view at 67 % — 82.53°
  • Horizontal field of view at 50 % — 61.89°
  • Horizontal field of view at 33 % — 41.26°

SMI3708 Wide

  • Focus adjustment — Available (0 ~ 35 D, automatic or manual)
  • Firmware file — fx2-cm5-imx708-v<version>.mender
  • Sensor capture mode — 2304 × 1296 (pixel array 4608 × 2592)
  • Output resolution — 1920 × 1080 (default), 1600 × 900, 1280 × 720, 640 × 360
  • Frame rate — 25 fps
  • Horizontal field of view at 100 % — 101.6°
  • Horizontal field of view at 67 % — 67.74°
  • Horizontal field of view at 50 % — 50.8°
  • Horizontal field of view at 33 % — 33.87°

Common Features

  • Image rotation — 0°, 180°
  • Field-of-view options — “100%”, “67%”, “50%”, “33%”

The horizontal field-of-view values are firmware defaults. Each device is calibrated before shipment, so actual values may differ slightly.

Hardware and Interfaces

  • Signal processing — FPGA and embedded controller
  • AI acceleration — Onboard NPU
  • Power input — 12 ~ 24 V DC or PoE+(IEEE 802.3at)
  • Power consumption — 14 W in standard mode, 21 W in maximum mode
  • Wired interfaces — Two Gigabit Ethernet ports (10/100/1000 Mbps), 4 ~ 20 mA analog output, RS485
  • Mounting — VESA 75, VESA 100, dedicated bracket
  • Ingress protection — IP68
  • Controls — One rear function button
  • Indicator — Status LED
  • Power protection — Reverse-polarity protection circuit
  • Corrosion resistance — Anti-corrosion surface treatment

※ The interface cable extending from the device is a multi-cable. Connect an Ethernet cable to the LAN connector at the end of the multi-cable. Use a CAT5e or higher UTP Ethernet cable. CAT6 is recommended, as is an installation length of no more than 80 m.

Multi-Cable

The multi-cable is permanently attached to the rear of the product.

Diagram showing the multi-cable’s five connectors—Loop(4-20mA), DC jack, LAN, PoE, and RS-485—and each connector’s wire colors and pin assignments

  • Loop(4-20 mA) — 2-pin terminal. Yellow +, gray −
  • DC jack — 5.5 × 2.1 mm. White +, black −, AWG24. Input voltage is 12 ~ 24 V DC.
  • LAN — RJ-45(T568B), built-in transformer
  • PoE — eth0 port. RJ-45(T568B)
  • RS-485 — Female D-Sub 9-pin. Pin 3: purple B(TXD+); pin 5: brown GND; pin 8: pink A(TXD−). The remaining pins are unused.

Software Features

  • Real-time sound-source display — Heatmap, peak markers, and level (dB) overlaid on the camera image
  • AI detection — Leak AI, partial discharge AI
  • Events — Automatic saving and saving based on level trigger, LEAK AI, or partial discharge AI conditions
  • Event files — Images (JPG), video (MP4), audio (WAV), measurement data (HDF5)
  • Development integration — REST API, WebSocket
  • PC software — FX Viewer
  • Robot integration — ROS 2

Network and Protocols

  • Network interfaces — Two Gigabit Ethernet (RJ-45) ports
  • Factory-default addresses — eth0 192.168.0.80, eth1 192.168.0.81
  • Device Manager — HTTP port 80
  • Video stream — H.264 Baseline, 25 fps, up to 1080p
  • RTSP — rtsp://<device-ip>:8554/overlay, no authentication, TCP, UDP unicast, UDP multicast
  • WebRTC — Used for video in Device Manager, no authentication
  • ONVIF — Supports device information, profiles, GetStreamUri, and GetSnapshotUri
  • Modbus TCP — Disabled by default, default port 5020
  • ROS 2 — Jazzy, five topics
  • Data interface — WebSocket (real-time acoustic data and measurement results), no authentication
  • Control API — REST API
  • Time — NTP

※ The BATCAM FX2 has no RTC (built-in clock). If power is turned off while the device is disconnected from a time server (NTP), it loses the device time. If powered on without NTP, the device time starts at 1970-01-01T00:00:00.

※ The BATCAM FX2 is not officially ONVIF-conformant. ONVIF functionality is only partially implemented. For details, see External System Integration.

※ In firmware v1.1.0, RTSP, WebRTC, WebSocket, ONVIF snapshots, event files, ONVIF device discovery and queries, Modbus TCP, and ROS 2 do not require authentication. For details, see External System Integration.

Pre-release software (v1.1.1-beta.1)

This information applies to firmware v1.1.1-beta.1 and may change in the official release.

  • RTSP — Requires a device account (Basic), unicast (TCP, UDP)
  • WebRTC — Requires a device account
  • ROS 2 — Includes a video topic (JPEG, 25 Hz)
  • WebSocket — Requires a device account

※ A device account is required to receive RTSP, WebRTC, WebSocket, ONVIF snapshots, and event files. An administrator can disable authentication for these streams. ONVIF device discovery and queries, Modbus TCP, and ROS 2 (including the video topic) do not require authentication.

Environment

  • Operating temperature — -20 ~ 50 °C
  • Storage temperature — -40 ~ 70 °C
  • Operating humidity — 93 % RH at 30 °C, non-condensing
  • Ingress protection — IP68

Package Contents

The standard package contains the following items.

  • BATCAM FX2 main unit
  • DC to Pigtail cable, 0.5 m
  • LAN cable (CAT6, 0.5 m)
  • 485 to Pigtail cable (485 to USB converter)
  • Waterproof PoE connector
  • Standard installation kit (swing mount)
  • DC 12 ~ 24 V adapter
  • Quick manual, product inspection report

Certifications and Tests

  • Product certifications — CE, FCC, KC, RoHS
  • Shock test — 15 g, 11 ms (Half-sine), three times in each of six directions (KS C IEC 60068-2-27)
  • Vibration test — MIL-STD-810H Method 514.8, Category 4 (vertical 1.08 g rms, lateral 0.21 g rms, longitudinal 0.76 g rms, one hour each)
  • Temperature test — -20 ~ 50 °C (KS C IEC 60068-2-1, 60068-2-2)
  • Humidity test — 30 °C, 93 % RH, 24 hours (KS C IEC 60068-2-78)

Specifications are subject to change without notice to improve the product.