Skip to content

System Settings

In the Settings menu, you can set the language, network, and time, restart services, and perform a factory reset. This page explains each item in the Settings menu and how to use the Metrics menu.

The Settings screen shows the following items from top to bottom.

  • Language Settings
  • Network Settings
  • Time Settings
  • Service Restart
  • Factory Reset

Network Settings, Time Settings, Service Restart, and Factory Reset require administrator privileges. For what appears under a regular user account, see User Accounts and Permissions.

Settings screen. From top to bottom: Language Settings, Network Settings, Time Settings, Service Restart, and Factory Reset.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

Stream Authentication appears between Time Settings and Service Restart. It is visible only to administrator accounts and requires administrator privileges.

Settings screen. From top to bottom: Language Settings, Network Settings, Time Settings, Stream Authentication, Service Restart, and Factory Reset.

Language Settings

Choose the language displayed in Device Manager. Select from 한국어, English, 简体中文, 日本語, and Tiếng Việt. The screen reloads when you make a selection.

The language selection is saved in the browser for one year. It is not saved on the device, so you must choose it separately in each browser.

Network Settings

Set the IP addresses of the device’s two Ethernet ports, eth0 and eth1. Administrator privileges are required.

The table shows the interface, IP address, subnet mask, gateway, and configuration method. The configuration method is “DHCP” or “Manual”. Use the gear button at the end of each row to open its settings dialog.

Network Settings table showing the interface, IP address, subnet mask, gateway, and configuration method in rows for eth0 and eth1

Factory settings

  • eth0 port — 192.168.0.80, subnet mask 255.255.255.0, gateway 192.168.0.1
  • eth1 port — 192.168.0.81, subnet mask 255.255.255.0, no gateway

The eth1 port is intended for a direct connection to a PC. On a newly installed device, eth1 comes without a gateway. A device whose firmware has been updated retains its previously saved network settings.

Port settings dialog

Set the following in the “Network Configuration” dialog.

  • Connection method — “Automatic (DHCP)” or “Manual Configuration”
  • IP address, subnet mask — Required for manual configuration.
  • Default gateway — May be left blank.
  • Default DNS server — May be left blank.

If you choose “Automatic (DHCP)”, the IP address, subnet mask, default gateway, and default DNS server fields turn gray and cannot be edited.

The default DNS server field is prefilled with 1.1.1.1 every time you open the dialog. This is not a value loaded from the device. To use another DNS server, enter it yourself.

Network Configuration dialog with Manual Configuration selected and values entered for IP address, subnet mask, default gateway, and default DNS server

Input rules

Enter an IP address as four numbers separated by periods. Each number must be from 0 to 255. Numbers with two or more digits cannot start with 0. For example, enter 10 instead of 010. This is because the browser interprets 010 as an octal number.

If the format is invalid, “Invalid IP address format. (Example: 192.168.0.10)” appears. If any field has an invalid format, pressing “Save” displays “Check your input” and identifies the field.

Changes that disconnect you

If you change the address of the port you are currently using to connect, this screen will lose its connection to the device. In this case, a “You will be disconnected” dialog appears before the change is applied.

  • Changing one static IP address to another — The new address is shown. After applying the change, reconnect using the new address.
  • Changing a static IP address to DHCP — The new address is assigned by the DHCP server (such as a router), so it cannot be shown on the screen. Check the address assigned to the device by the DHCP server, then connect to it.

Press “Cancel” to leave everything unchanged. Press “Apply” to start the change.

You will be disconnected dialog showing a message that the change will disconnect this screen from the device, the new address, and Cancel and Apply buttons

The following changes are applied immediately without a confirmation dialog.

  • Changing DHCP to DHCP
  • Leaving the IP address unchanged
  • Changing a port other than the one used for the current connection

After applying the change, the screen waits up to 8 seconds for a response from the device. The result appears in the settings dialog.

  • “Settings sent. Reconnect using the new address:” and a link to the new address — The device confirmed the change.
  • “No response received, so it is not known whether the settings were applied. Try connecting to the new address. If that fails, save again:” — The result could not be confirmed. Try connecting to the new address; if you cannot connect, save again.

If you changed to DHCP, the messages above are replaced with “Settings sent. Check the new address assigned to the device by the DHCP server, then reconnect.” or “No response received, so it is not known whether the settings were applied. Check the device address on the DHCP server and try connecting. If that fails, save again.”

For a change that does not disconnect you, the settings dialog closes and the screen reloads when saving is complete.

DHCP and gateway behavior

  • If you change from a static IP address to DHCP and the DHCP server does not assign an address, the DHCP setting remains in effect. The device continues trying to obtain an address and accepts one when it becomes available. It does not revert to the previous static IP address.
  • If both ports have a gateway, eth0 is used for the default route.
  • Even if both ports are on the same subnet, each port responds through itself to requests sent to its own address. Connect using the address of the port with the cable attached.

Time Settings

Set the device’s time zone and time servers (NTP). Only an administrator can change the time settings. Regular user accounts can see the table but not the gear button.

The table shows the following items.

  • Time zone — The device’s time zone.
  • Device time — The device’s current time. The offset from UTC is also shown.
  • NTP — The synchronization status: “Disabled”, “Synchronizing”, or “Synchronized”.
  • Time server — The time server currently in use. If no server has been specified, “Default server” is shown.

The NTP and time server information is refreshed every 30 seconds.

Time Settings table showing the time zone, device time, NTP synchronized status, and time server

Time Settings dialog

Press the gear button to open the “Time Settings” dialog.

  • Time zone — Choose a “Region”, then a “City”. The selected time zone name appears in the dialog.
  • Automatic time synchronization — Turn NTP on or off. When it is off, the time is not synchronized and the time server list is disabled. The device has no RTC to maintain the time while power is off, so its time may be incorrect after it is powered on again with synchronization off.
  • Time servers — Specify up to five. The servers are tried in order from top to bottom. Use “Add Server” to add a row and the “X” at the end of a row to remove it.

In firmware v1.1.0, the Time Settings dialog says that, when automatic time synchronization is off, time continues based on the device’s RTC. This description is incorrect because the device has no RTC.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

The description of automatic time synchronization in the Time Settings dialog has changed. It now says that the device has no RTC to maintain the time while power is off, so its time may be incorrect after it is powered on again if automatic time synchronization is disabled.

Time Settings dialog in v1.1.1, with a note in the automatic time synchronization description that the device has no RTC

Enter servers as hostnames or IP addresses. If a format is invalid, “One or more server addresses are invalid. Enter a hostname or IP address.” appears, and you cannot save.

If you enter no time servers, the default servers time1.google.com, time2.google.com, time3.google.com, and time4.google.com are used. Check the Time Settings table to see which server is currently used for synchronization.

Time Settings dialog showing the region and city selectors, automatic time synchronization switch, and time server input rows

Press “Save” to apply the settings immediately. A service restart or reboot is not required. If you change the time servers, “Synchronizing” may appear briefly, and the time may jump significantly all at once.

Where time has an effect

  • AI operating time periods — Based on device time.
  • Recent events on Home and the time in the video status bar — Displayed in the device’s time zone.
  • Creation time in the Events menu — Displayed in the browser’s time zone.

Changing the time zone does not change the records of previously saved events. Only the displayed times change.

※ BATCAM FX2 has no RTC (built-in clock). If power is turned off while it is not connected to a time server (NTP), the device loses its time. When powered on without NTP, the device time starts at 1970-01-01T00:00:00. Specify a time server the device can reach. On an isolated network without an external connection, you can use a time server on-site. After powering on, check that the device time is correct under Settings → Time Settings.

Stream Authentication

This feature is available starting with firmware v1.1.1. In firmware v1.1.0, an account is not required for RTSP video, WebRTC video, WebSocket, ONVIF snapshots, or event files.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

Stream Authentication requires a device account for RTSP video, WebRTC video, WebSocket, ONVIF snapshots, and event files. It is on by default and can be changed only by an administrator. Regular user accounts do not see this item.

  • “Use Stream Authentication” switch — A change is saved and applied immediately. No reboot or service restart is required.
  • On — Enter a device account in the VMS, viewer, or script to receive video and data. Both administrator and regular user accounts work.
  • Off — Anyone can receive them without an account. Turn this off only when you must use an older VMS or viewer that cannot provide an account.

※ If you turn it back on after it has been off, video and WebSocket connections established without an account are disconnected. Video in Device Manager continues to play.

※ The Stream Authentication item also displays this notice: “ROS 2 topics (including camera video topics) are not subject to stream authentication, so anyone on the same DDS domain can receive them without an account. To protect them, we recommend placing the device on a separate network.” For details, see ROS 2 Integration.

※ The same setting can be changed through REST PATCH /setting/stream ({"auth": false} or {"auth": true}). An administrator account is required.

Stream Authentication item in the Settings menu, showing the Use Stream Authentication switch and a yellow warning that an account is required

For details, see Security and Accounts under External System Integration.

Metrics

Use the Metrics menu to view graphs of the device’s CPU load, temperature, core frequency, and humidity. The menu is named “Metrics”, and the screen title is “System Metrics”. Both administrators and regular users can view it.

There are four graphs.

  • CPU load — Measured in %.
  • Temperature — Shows CPU and board temperatures in °C.
  • Core frequency — Measured in MHz.
  • Humidity — Measured in %.

Values update every 5 seconds, and the most recent hour is shown. The horizontal axis shows time in the browser’s time zone. Hover over a graph to see values.

Metrics screen with four graphs—CPU load, temperature, core frequency, and humidity—arranged in two rows and two columns

Use these graphs to check how temperature and humidity change in the installation environment. Compare the values at the installation site with the operating temperature and humidity ranges in Product Specifications and Configuration. If a sensor cannot read a value, its graph is empty.

Service Restart

Restart the measurement and video programs without turning off the device. Administrator privileges are required.

Pressing “Restart” starts the process immediately, without a confirmation dialog. Check any work in progress before pressing it.

  • Video and measurements pause briefly. AI and ROS 2 also restart.
  • Device Manager may briefly stop responding.
  • After the request is sent, “Restarting services” appears. If the request succeeds, it changes to “Services restarted”. Video and measurements may resume shortly afterward.
  • The device does not reboot.

Video and measurement data usually resume within a few seconds after a service restart. Check the live screen to confirm that the video and measurements are updating.

A service restart is required after changing the resolution in the Camera menu. The resolution is saved to the settings immediately, but the change takes effect in the video only after the services restart.

Lower part of the Settings screen showing the Service Restart item and a red Restart button

Reboot

Device Manager has no reboot button. To restart the entire device, turn its power off and then on again. Developers can request a reboot through REST. For details, see API and Developer Integration.

Factory Reset

Delete settings, accounts, and events, and return the device to its factory state. Administrator privileges are required.

Pressing “Reset” starts the process immediately, without a confirmation dialog. Before pressing it, download any events you need and record your settings. A factory reset cannot be undone once it starts.

What is deleted

  • All accounts — Restored to the factory-default accounts.
  • All settings — Network, camera, AI, ROS 2, Modbus TCP, and event settings return to their factory defaults.
  • The entire event list and all event files
  • System logs

What remains

  • Camera calibration values — Camera center and field-of-view calibration values.
  • Installed firmware and FPGA

※ Reinstalling the device image deletes the device-specific camera calibration values. Contact your service representative before reinstalling it.

After the reset

“Factory reset in progress” appears, and you are immediately logged out and taken to the login screen. The device stops all services and then reboots.

  • Network — eth0 returns to 192.168.0.80 and eth1 to 192.168.0.81. Set your PC’s network to this address range, then reconnect.
  • Login — Log in with the factory-default administrator account (ID admin, password 1234). The same credentials are shown in a notice below the login screen. You must change the password after your first login.

In firmware v1.1.0, other browsers and programs can continue using login credentials (tokens) obtained before the factory reset for up to 24 hours after they were issued.

Pre-release software (v1.1.1-beta.1)

This information is based on firmware v1.1.1-beta.1 and may change in the official release.

  • Other browsers and programs — All login credentials (tokens) obtained before the factory reset become invalid. You must log in again.
  • Stream Authentication — Returns to On.

If you perform a factory reset remotely, the device address may change and prevent you from reconnecting.