First Connection
You can connect to a factory-default BATCAM FX2 from a PC for the first time, change the password, and complete the initial setup. Install the device and connect power before proceeding.
1. Factory-default network
The factory-default Ethernet port settings are as follows.
- eth0 port — IP 192.168.0.80, subnet mask 255.255.255.0, gateway 192.168.0.1
- eth1 port — IP 192.168.0.81, subnet mask 255.255.255.0, no gateway
The eth1 port is intended for a direct PC connection. Even though both ports are on the same subnet (192.168.0.x), connect using the address of the port to which the cable is plugged in.
2. Set up the PC network
Set the PC’s wired network to the same 192.168.0.x subnet as the device. For example:
- IP address — 192.168.0.10
- Subnet mask — 255.255.255.0
Connect the PC and device directly with an Ethernet cable or connect them to the same switch. Choose a PC address that does not conflict with the device addresses (192.168.0.80, 192.168.0.81).
3. Connect
Enter http://192.168.0.80 in the PC’s web browser address bar. The login screen opens.

Pre-release software (v1.1.1-beta.1)
This information is based on firmware v1.1.1-beta.1 and may change in the official release.

The v1.1.1 login screen has a “User Manual” link and QR code. If you cannot open the online manual on a PC connected directly to the device, scan the QR code with a phone that has internet access.
※ The device is accessible only over HTTP. There is no HTTPS address.
4. Log in
The factory-default administrator account has the ID admin and password 1234. The same values appear in the instructions below the login form. Enter them in “User ID” and “Password,” then click “Console Login.”
After you log in, Device Manager opens. The screen title is FX2 Device Management Console. The login remains valid for 24 hours.
※ If login fails, an error message may appear in English.
For details, see Device Manager Screen Layout.
5. Change the password
When you log in with the initial password (1234), you are automatically taken to the “Change Password” screen. Enter the same value in “New Password” and “Confirm Password,” then click “Change Password.” After the change, you are immediately logged in with the new password and Device Manager opens.

- The password must be at least 4 characters long.
- You cannot reuse the initial password (
1234). - Changing a password requires administrator privileges. Standard user accounts cannot change their own passwords. An administrator must change them in the User menu.
※ This screen opens automatically only when you log in with the initial password. You can use Device Manager without changing the password, but you must change it after the first connection.
For details, see User Accounts and Permissions.
6. Initial settings
Configure the following settings in order. You must be logged in with an administrator account.
1) Time
Under Settings → Time Settings, click the gear button to set the time zone and time server (NTP). Event timestamps and AI operating hours are based on the device time.
※ BATCAM FX2 does not have an RTC (built-in clock). If power is turned off while the device is not connected to a time server (NTP), it loses the device time. Without NTP, the device time starts at 1970-01-01T00:00:00 when power is turned on. Specify a time server the device can access. On an isolated network without an external connection, use a local time server.
2) Network and IP address
To install multiple devices on the same network or match the site network, go to Settings → Network Settings and use the gear button at the end of the eth0 or eth1 row to change its address. For “Connection Method,” choose “Automatic (DHCP)” or “Manual Configuration.”
If you change the address you are currently using to connect, a “Connection will be lost” confirmation dialog appears. Clicking “Apply” disconnects this screen from the device. After applying the change, reconnect using the new address. If you switch to “Automatic (DHCP),” check the DHCP server for the device’s new address.
- Enter IP addresses without leading zeros. Example: 192.168.0.10
- Changing a port other than the one you are using to connect does not disconnect you.
For details, see System Settings.
3) Camera field of view and installation check
Check the video in the Camera menu and set the field of view. Adjust the device’s orientation so that the measurement target is centered on the screen. For details, see Camera Settings.
4) Check event triggers
Under Events → Trigger Conditions, check the conditions under which events are saved. For details, see Events.
7. Install multiple devices
All factory-default devices use the same addresses. Before connecting them to the same network, connect each device one at a time and assign it a unique IP address. Address conflicts make connections unstable.